Latest News

Toeboard Compliance for AS1657 Applications

Posted by Elle Green on 03 Nov, 2017
Elle Green

A toeboard system is to be installed on walkways where;

• there is no permanent structure with 10mm of the edge

• an object could fall to where persons have access to the area below the walkway.

 

As shown to the left, a toeboard system is required due to the fall-off from the edge of the platform.

toeboard compliance.png


For the toeboard system to be compliant in the above scenario;

• it must have a gap no greater than 10mm between the underside of the toeboard and the walkway

• the toeboard shall not be less than 100mm above the floor

 

toeboard compliance 2.png

 

To save time, resource and ease of installation when specifying Moddex stair handrails or balustrades please consult the Hot Design Tip or contact us on 1800 663 339 or sales@moddex.com.au

Topics: Design Tip, compliance, toeboard